- Range of product
- Altivar 61 Plus
- Product or component type
- Variable speed drive
- Device short name
- ATV61
- Product destination
- Synchronous motors Asynchronous motors
- Product specific application
- Pumping and ventilation machine
- Assembly style
- In floor-standing enclosure with separate air flows
- product composition
- An IP65 remote mounting kit for graphic display terminal A plinth A switch and fast-acting fuses A line choke in an additional enclosure ATV61HC50Y standard drive IP00 Terminals/bars for motor connection A wired ready-assembled Sarel Spacial 6000 enclosure
- EMC filter
- Integrated
- Network number of phases
- 3 phases
- rated supply voltage
- 690 V +/- 10 %
- Supply frequency
- 50...60 Hz
- Motor power kW
- 500 kW, 3 phases at 690 V
- Line current
- 505 A at 690 V3 phases / 500 kW
- IP degree of protection
- IP54
- Apparent power
- 604 kVA for 690 V, 3 phases 500 kW
- Prospective line Isc
- 100 kA with external fuses
- Continuous output current
- 543 A, 2.5 kHz at 690 V 3 phases
- Maximum transient current
- 652 A for 60 s, 3 phases
- Speed drive output frequency
- 0.1…500 Hz
- Nominal switching frequency
- 2.5 kHz
- Switching frequency
- 2.5...4.9 kHz with derating factor 2...4.9 kHz adjustable
- Speed range
- 1…100 in open-loop mode, without speed feedback
- Speed accuracy
- +/- 10 % of nominal slip 0.2 Tn to Tn without speed feedback
- Torque accuracy
- +/- 15 % in open-loop mode, without speed feedback
- Transient overtorque
- 120 % of nominal motor torque for 60 s 135 % of nominal motor torque for 2 s
- Braking torque
- 30 % without braking resistor <= 125 % with braking resistor
- Asynchronous motor control profile
- Voltage/frequency ratio, 2 points Voltage/frequency ratio, 5 points Voltage/frequency ratio - Energy Saving, quadratic U/f Flux vector control without sensor, standard
- Synchronous motor control profile
- Vector control without sensor, standard
- Regulation loop
- Adjustable PI regulator
- Motor slip compensation
- Automatic whatever the load Adjustable Suppressable Not available in voltage/frequency ratio (2 or 5 points)
- Supply voltage limits
- 621…759 V
- Network frequency limits
- 47.5…63 Hz
- Overvoltage category
- Class 3 conforming to EN 50178
- Local signalling
- LCD display unit for operation function, status and configuration - mounted in the front door
- Output voltage
- <= supply voltage
- Isolation
- Electrical between power and control
- type of cable for external connection
- IEC cable at 40 °C, copper 70 °C / PVC
- Electrical connection
- Terminal - 2.5 mm² / 14 AWG (AI1-/AI1+, AI2, AO1, R1A, R1B, R1C, R2A, R2B, LI1...LI6, PWR) entry from the bottom Bar M12 - 4 x 300 mm² (L1/R, L2/S, L3/T) entry from the bottom Bar M12 - 4 x 240 mm² (U/T1, V/T2, W/T3) entry from the bottom
- Motor recommanded cable cross section
- 3 (3 x 150) mm²
- Short-circuit protection
- 800 A fuse protection type gI - power supply upstream