- Range of product
- Altivar 71 Plus
- Product or component type
- Variable speed drive
- Device short name
- ATV71 Plus
- Product destination
- Asynchronous motors Synchronous motors
- Product specific application
- Complex, high-power machines
- Assembly style
- In floor-standing enclosure compact version
- product composition
- An IP65 remote mounting kit for graphic display terminal A line choke ATV71HC13Y drive on heatsink A switch and fast-acting semi-conductor fuses A wired ready-assembled Sarel Spacial 6000 enclosure Terminals/bars for motor connection
- EMC filter
- Integrated
- Network number of phases
- 3 phases
- rated supply voltage
- 690 V +/- 10 %
- Supply voltage limits
- 621…759 V
- Supply frequency
- 50...60 Hz +/- 5 %
- Network frequency
- 47.5...63 Hz
- Motor power kW
- 132 kW at 690 V
- Line current
- 137 A for 690 V / 132 kW
- Apparent power
- 164 kVA for 690 V / 132 kW
- Prospective line Isc
- 100 kA with external fuses
- Continuous output current
- 150 A at 2.5 kHz, 690 V / 132 kW
- Maximum transient current
- 225 A for 60 s / 132 kW
- Speed drive output frequency
- 0…500 Hz
- Nominal switching frequency
- 2.5 kHz
- Switching frequency
- 2.5...4.9 kHz with derating factor 2...4.9 kHz adjustable
- Speed range
- 1…100 in open-loop mode, without speed feedback
- Speed accuracy
- +/- 0.01 % of nominal speed in closed-loop mode with encoder feedback 0.2 Tn to Tn +/- 10 % of nominal slip without speed feedback 0.2 Tn to Tn
- Torque accuracy
- +/- 15 % in open-loop mode, without speed feedback +/- 5 % in closed-loop mode with encoder feedback
- Transient overtorque
- 170 % of nominal motor torque +/- 10 % for 60 s 220 % of nominal motor torque +/- 10 % for 2 s
- Braking torque
- 30 % without braking resistor
- Asynchronous motor control profile
- Flux vector control without sensor, 2 points Flux vector control without sensor, standard Voltage/frequency ratio, 5 points Voltage/frequency ratio - Energy Saving, quadratic U/f Voltage/frequency ratio, 2 points Flux vector control without sensor, ENA (energy Adaptation) system Flux vector control...
- Synchronous motor control profile
- Vector control without sensor, standard Vector control with sensor, standard
- Regulation loop
- Adjustable PI regulator
- Motor slip compensation
- Adjustable Automatic whatever the load Suppressable Not available in voltage/frequency ratio (2 or 5 points)
- Overvoltage category
- Class 3 conforming to EN 50178
- Local signalling
- LCD display unit for operation function, status and configuration
- Output voltage
- <= power supply voltage
- Isolation
- Electrical between power and control
- type of cable for external connection
- IEC cable at 40 °C, copper 70 °C / PVC
- Electrical connection
- Terminal M10 - 2 x 150 mm² (U/T1, V/T2, W/T3) entry from the bottom Terminal - 2.5 mm² / 14 AWG (AI1-/AI1+, AI2, AO1, R1A, R1B, R1C, R2A, R2B, LI1...LI6, PWR) entry from the bottom Terminal M8 - 2 x 120 mm² (L1/R, L2/S, L3/T) entry from the bottom
- Motor recommanded cable cross section
- 3 x 70 mm²
- Short-circuit protection
- 200 A fuse protection type gI - power supply upstream
- Supply
- External supply: 24 V DC (19…30 V), Internal supply for reference potentiometer: 10 V DC (10…11 V), Internal supply: 24 V DC (21…27 V), <100 mA